3,455 research outputs found

    Older adults who have previously fallen due to a trip walk differently than those who have fallen due to a slip

    Get PDF
    Studying the relationships between centre of mass (COM) and centre of pressure (COP) during walking has been shown to be useful in determining movement stability. The aim of the current study was to compare COM–COP separation measures during walking between groups of older adults with no history of falling, and a history of falling due to tripping or slipping. Any differences between individuals who have fallen due to a slip and those who have fallen due to a trip in measures of dynamic balance could potentially indicate differences in the mechanisms responsible for falls. Forty older adults were allocated into groups based on their self-reported fall history during walking. The non-faller group had not experienced a fall in at least the previous year. Participants who had experienced a fall were split into two groups based on whether a trip or slip resulted in the fall(s). A Vicon system was used to collect full body kinematic trajectories. Two force platforms were used to measure ground reaction forces. The COM was significantly further ahead of the COP at heel strike for the trip (14.3 ± 2.7 cm) and slip (15.3 ± 1.1 cm) groups compared to the non-fallers (12.0 ± 2.7 cm). COM was significantly further behind the COP at foot flat for the slip group (−14.9 ± 3.6 cm) compared to the non-fallers (−10.3 ± 3.9 cm). At mid-swing, the COM of the trip group was ahead of the COP (0.9 ± 1.6 cm), whereas for the slip group the COM was behind the COP (−1.2 ± 2.2 cm). These results show identifiable differences in dynamic balance control of walking between older adults with a history of tripping or slipping and non-fallers

    Investigating the effect of thermal gradients on stress in solid oxide fuel cell anodes using combined synchrotron radiation and thermal imaging

    Get PDF
    Thermal gradients can arise within solid oxide fuel cells (SOFCs) due to start-up and shut-down, non-uniform gas distribution, fast cycling and operation under internal reforming conditions. Here, the effects of operationally relevant thermal gradients on Ni/YSZ SOFC anode half cells are investigated using combined synchrotron X-ray diffraction and thermal imaging. The combination of these techniques has identified significant deviation from linear thermal expansion behaviour in a sample exposed to a one dimensional thermal gradient. Stress gradients are identified along isothermal regions due to the presence of a proximate thermal gradient, with tensile stress deviations of up to 75Â MPa being observed across the sample at a constant temperature. Significant strain is also observed due to the presence of thermal gradients when compared to work carried out at isothermal conditions

    Cord blood group 2 innate lymphoid cells are associated with lung function at 6 weeks of age.

    Full text link
    Objective: Offspring born to mothers with asthma in pregnancy are known to have lower lung function which tracks with age. Human group 2 innate lymphoid cells (ILC2) accumulate in foetal lungs, at 10-fold higher levels compared to adult lungs. However, there are no data on foetal ILC2 numbers and the association with respiratory health outcomes such as lung function in early life. We aimed to investigate cord blood immune cell populations from babies born to mothers with asthma in pregnancy. Methods: Cord blood from babies born to asthmatic mothers was collected, and cells were stained in whole cord blood. Analyses were done using traditional gating approaches and computational methodologies (t-distributed stochastic neighbour embedding and PhenoGraph algorithms). At 6 weeks of age, the time to peak tidal expiratory flow as a percentage of total expiratory flow time (tPTEF/tE%) was determined as well as Lung Clearance Index (LCI), during quiet natural sleep. Results: Of 110 eligible infants (March 2017 to November 2019), 91 were successfully immunophenotyped (82.7%). Lung function was attempted in 61 infants (67.0%), and 43 of those infants (70.5% of attempted) had technically acceptable tPTEF/tE% measurements. Thirty-four infants (55.7% of attempted) had acceptable LCI measurements. Foetal ILC2 numbers with increased expression of chemoattractant receptor-homologous molecule (CRTh2), characterised by two distinct analysis methodologies, were associated with poorer infant lung function at 6 weeks of age." Conclusion: Foetal immune responses may be a surrogate variable for or directly influence lung function outcomes in early life

    Controlled versus free breathing for multiple-breath nitrogen washout in asthma.

    Full text link
    The lack of comparability in indices of ventilation heterogeneity between free- and controlled-breathing MBNW protocols is confirmed in asthma https://bit.ly/3lmri4A

    Australian Enterococcal Sepsis Outcome Programme, 2011

    Full text link
    From 1 January to 31 December 2011, 29 institutions around Australia participated in the Australian Enterococcal Sepsis Outcome Programme (AESOP). The aim of AESOP 2011 was to determine the proportion of enterococcal bacteraemia isolates in Australia that are antimicrobial resistant, with particular emphasis on susceptibility to ampicillin and the glycopeptides, and to characterise the molecular epidemiology of the Enterococcus faecalis and E. faecium isolates. Of the 1,079 unique episodes of bacteraemia investigated, 95.8% were caused by either E. faecalis (61.0%) or E. faecium (34.8%). Ampicillin resistance was detected in 90.4% of E. faecium but not detected in E. faecalis. Using Clinical and Laboratory Standards Institute breakpoints (CLSI), vancomycin non-susceptibility was reported in 0.6% and 31.4% of E. faecalis and E. faecium respectively and was predominately due to the acquisition of the vanB operon. Approximately 1 in 6 vanB E. faecium isolates however, had an minimum inhibitory concentration at or below the CLSI vancomycin susceptible breakpoint of ≤ 4 mg/L. Overall, 37% of E. faecium harboured vanA or vanB genes. Although molecular typing identified 126 E. faecalis pulsed-field gel electrophoresis (PFGE) pulsotypes, more than 50% belonged to 2 pulsotypes that were isolated across Australia. E. faecium consisted of 73 PFGE pulsotypes from which 43 multilocus sequence types were identified. Almost 90% of the E. faecium were identified as clonal complex 17 clones, of which approximately half were characterised as sequence type 203, which was isolated Australia-wide. In conclusion, the AESOP 2011 has shown that although polyclonal, enterococcal bacteraemias in Australia are frequently caused by ampicillin-resistant vanB E. faecium

    The moderating role of overcommitment in the relationship between psychological contract breach and employee mental health

    Get PDF
    Reimann M. The moderating role of overcommitment in the relationship between psychological contract breach and employee mental health. JOURNAL OF OCCUPATIONAL HEALTH. 2016;58(4-5):425-433.Objectives: This study investigated whether the association between perceived psychological contract breach (PCB) and employee mental health is moderated by the cognitive-motivational pattern of overcommitment (OC). Linking the psychological contract approach to the effort-reward imbalance model, this study examines PCB as an imbalance in employment relationships that acts as a psychosocial stressor in the work environment and is associated with stress reactions that in turn negatively affect mental health. Methods: The analyses were based on a sample of 3,667 employees who participated in a longitudinal linked employer employee survey representative of large organizations (with at least 500 employees who are subject so social security contributions) in Germany. Fixed-effects regression models, including PCB and OC, were estimated for employee mental health, and interaction effects between PCB and OC were assessed. Results: The multivariate fixed-effects regression analyses showed a significant negative association between PCB and employee mental health. The results also confirmed that OC does indeed significantly increase the negative effect of PCB on mental health and that OC itself has a significant and negative effect on mental health. Conclusions: The results suggest that employees characterized by the cognitive-motivational pattern of OC are at an increased risk of developing poor mental health if they experience PCB compared with employees who are not overly committed to their work. The results of this study support the assumption that psychosocial work stressors play an important role in employee mental health

    How often should we monitor for reliable detection of atrial fibrillation recurrence? Efficiency considerations and implications for study design

    Get PDF
    OBJECTIVE: Although atrial fibrillation (AF) recurrence is unpredictable in terms of onset and duration, current intermittent rhythm monitoring (IRM) diagnostic modalities are short-termed and discontinuous. The aim of the present study was to investigate the necessary IRM frequency required to reliably detect recurrence of various AF recurrence patterns. METHODS: The rhythm histories of 647 patients (mean AF burden: 12±22% of monitored time; 687 patient-years) with implantable continuous monitoring devices were reconstructed and analyzed. With the use of computationally intensive simulation, we evaluated the necessary IRM frequency to reliably detect AF recurrence of various AF phenotypes using IRM of various durations. RESULTS: The IRM frequency required for reliable AF detection depends on the amount and temporal aggregation of the AF recurrence (p<0.0001) as well as the duration of the IRM (p<0.001). Reliable detection (>95% sensitivity) of AF recurrence required higher IRM frequencies (>12 24-hour; >6 7-day; >4 14-day; >3 30-day IRM per year; p<0.0001) than currently recommended. Lower IRM frequencies will under-detect AF recurrence and introduce significant bias in the evaluation of therapeutic interventions. More frequent but of shorter duration, IRMs (24-hour) are significantly more time effective (sensitivity per monitored time) than a fewer number of longer IRM durations (p<0.0001). CONCLUSIONS: Reliable AF recurrence detection requires higher IRM frequencies than currently recommended. Current IRM frequency recommendations will fail to diagnose a significant proportion of patients. Shorter duration but more frequent IRM strategies are significantly more efficient than longer IRM durations. CLINICAL TRIAL REGISTRATION URL: Unique identifier: NCT00806689

    Identifying the Origins of Microstructural Defects Such as Cracking within Ni‐Rich NMC811 Cathode Particles for Lithium‐Ion Batteries

    Get PDF
    The next generation of automotive lithium‐ion batteries may employ NMC811 materials; however, defective particles are of significant interest due to their links to performance loss. Here, it is demonstrated that even before operation, on average, one‐third of NMC811 particles experience some form of defect, increasing in severity near the separator interface. It is determined that defective particles can be detected and quantified using low resolution imaging, presenting a significant improvement for material statistics. Fluorescence and diffraction data reveal that the variation of Mn content within the NMC particles may correlate to crystallographic disordering, indicating that the mobility and dissolution of Mn may be a key aspect of degradation during initial cycling. This, however, does not appear to correlate with the severity of particle cracking, which when analyzed at high spatial resolutions, reveals cracking structures similar to lower Ni content NMC, suggesting that the disconnection and separation of neighboring primary particles may be due to electrochemical expansion/contraction, exacerbated by other factors such as grain orientation that are inherent in such polycrystalline materials. These findings can guide research directions toward mitigating degradation at each respective length‐scale: electrode sheets, secondary and primary particles, and individual crystals, ultimately leading to improved automotive ranges and lifetimes
    corecore